Analysis of Energy Quality and Charge Status in a Sectioning Station and Energy Transformation

Keywords: Power quality, , voltage imbalance, transformer load

Abstract

This work presents the application of a procedure for the analysis of energy quality, specific to voltage deviation and unbalance, in a sectioning and energy transformation (PT) station, as well as evaluating the state of charge of its main elements. In order to carry out the procedure, it is not necessary to carry out invasive or very expensive tests.The work describes the steps of the procedure and deals with the main theoretical aspects applied to stories such as power quality problems, with emphasis on voltage imbalance and deviation.The procedure is applied in the (PT) of the Torre do Tombo neighborhood, in the city of Namibe, belonging to the National Electricity Company (ENE) of the Republic of Angola. For each voltage and current reading, the parameters and curves that allowed evaluating the state of charge of the transformer, the circuit breakers and the conductors of each circuit of the (PT) were determined, as well as performing an analysis of the power quality of one of the circuits, detecting power quality problems and poor selection of circuit

Downloads

Download data is not yet available.

References

Bertolli, M., Roark, G., Urrutia, S., & Chiodi, F. (2017). Revisión de modelos de madurez en la medición del desempeño. INGE CUC, 13(1), 70-83. https://doi.org/10.17981/ingecuc.13.1.2017.07

. CEDAM, “Cables de Alta Seguridad”, cedam.com http://www.cedam.com.ar/IMAGENES/PDF/111)%20CEDASEG%20OIL%20Subterraneo%20PVC%201,1%20kv%20Tetrapolar.pdf (visitado Noviembre, 2008).

. Duarte Forero, J., Guillín Estrada, W., & Sánchez Guerrero, J. (2018). Desarrollo de una metodología para la predicción del volumen real en la cámara de combustión de motores diésel utilizando elementos finitos. INGE CUC, 14(1), 122-132. https://doi.org/10.17981/ingecuc.14.1.2018.11

. Colectivo de Autores. Gestión Energética Empresarial. La Habana, CU: Centro de Estudios de Energía y Medio Ambiente, CEEMA, Universidad de Cienfuegos, 2001.

Cables submarinos, “Conductores Eléctricos”, cablessubmarinos-blog.com. http://cablesubmarino.wordpress.com/2008/03/13/conductores-electricos/ (visitado Noviembre, 2008).

Wikipedia, “Disyuntor” Wikipedia.com. http://es.wikipedia.org/wiki/Disyuntor (visitado: Diciembre, 2008).

EJM, “Especificação de Disjuntores Segundo a ABNT”, ejm.com.br. www.ejm.com.br/download/disjuntores_x_normas_abnt.pdf (visitado Diciembre, 2008).

A. A. Feodorov y E. Rodríguez. Suministro eléctrico de empresa industriales, La Habana, CU: Pueblo y Educación, 1987.

A. A. Feodorov y E. Rodríguez. Suministro eléctrico de empresa industriales, La Habana, CU: Pueblo y Educación, 1987.

V. Sousa, “Determinación de la eficiencia de motores asincrónicos en condiciones de campo y en presencia de desbalance de tensión”, Tesis Master, Fac. Ing., UCF, Cienfuegos, CU, 2006. https://doi.org/10.13140/RG.2.2.25332.14727

C. Yin Lee, “Effects on Unbalanced Voltage on the operation Performance of a Three Phase Induction Motor”, IEEE T Energy Conver, vol 14, no 2, pp. 202–208. Jun. 1999. https://doi.org/10.1109/60.766984

Published
2020-07-14
How to Cite
Sousa Santos, V., & Gómez Sarduy, J. (2020). Analysis of Energy Quality and Charge Status in a Sectioning Station and Energy Transformation. International Journal of Management Science and Operations Research, 4(1). https://doi.org/10.17981/ijmsor.v4i1.109